Art and Engineering

Pump & System Curve Simulator

Pump curve against the system curve: operating point, efficiency and shaft power, affinity laws for speed (VFD) and impeller trim, pumps in parallel or series, NPSH available vs required with a cavitation margin check, using ASME B36.10 pipe sizes and Darcy–Weisbach/Colebrook friction.

Pump

m
L/min
m
L/min
m
L/min
%
m
m

Speed, trim and pumps

%

1,450 rpm (VFD)

%

260 mm

Operating point

Head vs flow0102030405001,0002,0003,0004,000Flow (L/min)Head (m)PumpSystem
Efficiency02040608001,0002,0003,0004,000Flow (L/min)%Each pump
NPSH051001,0002,0003,0004,000Flow (L/min)mAvailableRequired

Fluid and piping

kPa

ID 102.3 mm

m
m
kPa
m
m
kPa

Typical ΣK values are listed in the pressure drop calculator. Negative suction level = suction lift.

Duty point

Flow
1,426L/min
Head
26.62m
Efficiency
76.4%
Shaft power
8.11kW
Flow vs BEP (each pump)
85.6%
Pipe velocity
2.89m/s
Hydraulic power
6.194kW
Discharge pressure rise
260.6kPa

Preferred operating region: 70–120 % of BEP flow (ANSI/HI 9.6.3).

Cavitation check

Good margin
NPSH available
10.6m
NPSH required
2.745m
Margin ratio NPSHa/NPSHr
3.86

ANSI/HI 9.6.1 suggests a margin ratio of at least 1.1, and 1.3–1.5 or more for many services.

Assumptions & limitations
  • Pump curves are fitted shapes through the points you enter: use the maker's curves for final selection.
  • Affinity laws for speed and impeller trim; NPSHr is scaled with speed² as an approximation.
  • Steady, incompressible flow; one pipe size for suction and discharge; viscosity corrections for thick fluids are not applied to the pump.
  • Parallel pumps are identical and share the flow equally; series pumps add head.