Pump & System Curve Simulator
Pump curve against the system curve: operating point, efficiency and shaft power, affinity laws for speed (VFD) and impeller trim, pumps in parallel or series, NPSH available vs required with a cavitation margin check, using ASME B36.10 pipe sizes and Darcy–Weisbach/Colebrook friction.
Pump
m
L/min
m
L/min
m
L/min
%
m
m
Speed, trim and pumps
%
1,450 rpm (VFD)
%
260 mm
Operating point
Fluid and piping
kPa
ID 102.3 mm
m
m
kPa
m
m
kPa
Typical ΣK values are listed in the pressure drop calculator. Negative suction level = suction lift.
Duty point
Flow
1,426L/min
Head
26.62m
Efficiency
76.4%
Shaft power
8.11kW
Flow vs BEP (each pump)
85.6%
Pipe velocity
2.89m/s
Hydraulic power
6.194kW
Discharge pressure rise
260.6kPa
Preferred operating region: 70–120 % of BEP flow (ANSI/HI 9.6.3).
Cavitation check
Good margin
NPSH available
10.6m
NPSH required
2.745m
Margin ratio NPSHa/NPSHr
3.86
ANSI/HI 9.6.1 suggests a margin ratio of at least 1.1, and 1.3–1.5 or more for many services.
Assumptions & limitations
- Pump curves are fitted shapes through the points you enter: use the maker's curves for final selection.
- Affinity laws for speed and impeller trim; NPSHr is scaled with speed² as an approximation.
- Steady, incompressible flow; one pipe size for suction and discharge; viscosity corrections for thick fluids are not applied to the pump.
- Parallel pumps are identical and share the flow equally; series pumps add head.