Art and Engineering

Venturi Generator

Classical Venturi tube with β ratio, cone angles and pressure taps; flow from Δp with q = C/√(1−β⁴)·(π/4)d²√(2Δp/ρ); STL/3MF, STEP and DXF.

Geometry

mm
°

ISO 5167-4: 21° ± 1°

°

7–15° (smaller recovers more pressure)

mm
mm
mm
mm

Flow

kPa
kg/m³

Water ≈ 998 kg/m³; air ≈ 1.2

Engineering ToolBox 0.975 typical; ISO 5167-4 0.984 (cast) – 0.995 (machined)

Model

Material

kg/m³

3D preview

Loading geometry engine…

Drag to orbit · pinch/scroll to zoom · right-drag to pan · exports in mm

Assumptions & limitations
  • Incompressible flow (liquids, or gases at small Δp); C is user-set.
  • Throat length = d; cone lengths from the included angles; taps at mid-inlet and mid-throat.
Limitations
  • A printed Venturi is for teaching and rough measurement; ISO 5167 accuracy needs the specified finish, straight runs and calibration.
  • No expansibility factor for gases.

Results are for general reference. Verify critical dimensions and values before cutting, machining, printing or relying on them for safety.